Wednesday, September 12, 2007
Stardust Yachts Problem: Label Certification Fuel System Source: Ppg Rbfv Model Year: 2007 Model Name: 1672 Wbss 72 Units: 8 Campaign Open Date: 9/12/2007 Campaign Close Date: 9/25/2007 Number: 07R2372S Severity Level: L Boat Type: Houseboats Comments: 1) no certification label. third time cited. 2) anti-siphon valves not installed. 9/12/07 rec'd dnr. sent cur. 9/18/07 [...]
Also filed in
|
|
Sumerset Acquisition Llc Problem: Ventilation Exhaust System Source: Ppg Rbfv Model Year: 2007 Model Name: 16 X 80 Houseboat Units: 179 Campaign Open Date: 8/13/2007 Campaign Close Date: 1/28/2008 Number: 07R2375S Severity Level: L Boat Type: Houseboats Comments: there is an internal opening allowing exhaust gases to return into the engine compartment. 9/12/07 rec'd dnr.179 [...]
Also filed in
|
|
Thursday, January 27, 2005
Sumerset Acquisition Llc Problem: Fuel System Source: Rbfv Ppg Model Year: 2005 Model Name: 16 X 68 Houseboat Units: 83 Campaign Open Date: 1/27/2005 Campaign Close Date: 6/15/2005 Number: 04R0389S Severity Level: L Boat Type: Houseboats Comments: mfr did not have anti-siphon valves installed from tank top to engine HIN: SAQ01072I405
Also filed in
|
|
Sunstar Houseboats Inc Problem: Electrical System Source: Rbfv Ppg Model Year: 2005 Model Name: 17 X 67 + 3 Houseboat Units: 5 Campaign Open Date: 1/14/2005 Campaign Close Date: 7/11/2005 Number: 04R0351S Severity Level: L Boat Type: Houseboats Comments: manufacturer is not grounding the cranking motor circuits as required by 33 cfr 183.415. there are [...]
Also filed in
|
|
Wednesday, November 19, 2003
Sharpe Houseboat Inc Problem: Electrical System Source: Accident Investigation Model Year: 1999 Model Name: Units: 123 Campaign Open Date: 11/19/2003 Campaign Close Date: 3/31/2004 Number: 030171S Severity Level: H Boat Type: Houseboats Comments: ancon marine investigated sharpe hb fire at bullfrog marina fuel dock lake powell. root cause reported to be spark from non-ignition protected [...]
Also filed in
|
|
Island Rover Houseboats Problem: Ventilation Blower Warning Label Source: Rni Model Year: 1998 Model Name: New 54 Units: 3 Campaign Open Date: 4/11/2003 Campaign Close Date: 7/22/2003 Number: 02R0897S Severity Level: L Boat Type: Houseboats Comments: boats deck fuel fill wasn't grounded; positive terminal of cranking motor starter is not protected against short-circuiting; cert. label; [...]
Also filed in
|
|
Sharpe Houseboat Inc Problem: Label Blower Warning Source: Rni Model Year: Model Name: 82×16 Wc Units: 205 Campaign Open Date: 10/25/2002 Campaign Close Date: 2/3/2003 Number: 02R0323S Severity Level: L Boat Type: Houseboats Comments:
Also filed in
|
|
Tuesday, October 22, 2002
Sumerset Houseboats Problem: Electrical System Source: Manufacturer Model Year: 93-99 Model Name: Various Units: 252 Campaign Open Date: 10/22/2002 Campaign Close Date: 7/23/2005 Number: 020189T Severity Level: H Boat Type: Houseboats Comments: shore power service circuit breakers on boats with dual shore power option improperly wired. manufacturer has determined some 92-99 models have multiple shore [...]
Also filed in
|
|
Monday, September 9, 2002
Skipperliner Houseboats Problem: Electrical Starter Term Fuel Fill Not Grounded Source: Rni Model Year: 2002 Model Name: Aquaminium 600 Units: 49 Campaign Open Date: 9/9/2002 Campaign Close Date: 5/25/2004 Number: 02R0322S Severity Level: H Boat Type: Houseboats Comments: positive terminal on starter not protected by boot or nipple. dnr recd 9/9/02. cur 1/3/03. cur #3 [...]
Also filed in
|
|
Funtime Houseboats Problem: Label Blower Warning Fuel System Not Press Tes Source: Rni Model Year: 2002 Model Name: Continental Units: 8 Campaign Open Date: 8/9/2002 Campaign Close Date: 10/1/2002 Number: 02R0345S Severity Level: L Boat Type: Houseboats Comments: wiring passing over structural members were not protected from abrasion. starboard running light has obstructed upper vertical [...]
Also filed in
|
|
Thoroughbred Cruisers Inc Problem: Electrical System Source: Rni Model Year: 2002 Model Name: 83 X 18 Units: 18 Campaign Open Date: 6/13/2002 Campaign Close Date: 7/26/2002 Number: 02R0284T Severity Level: H Boat Type: Houseboats Comments: during factory visit discovered bonding wire in washer/dryer and range was connected between neutral and ground. manufacturer volunteered to do [...]
Also filed in
|
|
Stoll Manufacturing Inc Problem: Fuel System Source: Rni Model Year: 2002 Model Name: Travelwave 360 Units: 2 Campaign Open Date: 5/22/2002 Campaign Close Date: 6/24/2002 Number: 02R0260S Severity Level: L Boat Type: Houseboats Comments: fuel fill connections were not secured with two adjacent metallic hose clamps. HIN: TVE00003F202
Also filed in
|
|
Norris Yachts Inc Problem: Breaker Not Ign. Protect Circuit Breakers Source: Rni Model Year: 2001 Model Name: 83 Ft. Wide Body Houseboat Units: 6 Campaign Open Date: 6/26/2001 Campaign Close Date: 8/31/2004 Number: 01R0065S Severity Level: L Boat Type: Houseboats Comments: main breaker for house battery-bank in the engine room was not ignition protected; 6 [...]
Also filed in
|
|
Stardust Cruisers Problem: Electrical System Non-Igniton Protected Par Source: Manufacturer Model Year: Model Name: Various Units: 343 Campaign Open Date: 3/22/2001 Campaign Close Date: 12/6/2005 Number: 010047T Severity Level: H Boat Type: Houseboats Comments: a relay (part number 1114) part of the mathers multi station propulsion control system is not igntion protected. the part is [...]
Also filed in
|
|
Wednesday, February 28, 2001
Fantasy Custom Yachts Problem: Generator Exhaust (co) Source: Fantasy Custom Yachts Model Year:
Also filed in
|
|